The OPTO-SA6200 handheld RF Spectrum Analyzer and Signal Generator with its amazingly quick measurement speed, sweeps the range of 35MHz to 6200 MHz in 0.25 seconds, scans 500 points with a high accuracy of 2dB within 70-75dB dynamic range. The large color 3.2" LCD Touch Screen with supplied stylus provides vivid data and ease of operation. The OPTO-SA6200 can detect signals from Wi-Fi, 2G, 3G, 4G, LTE, CDMA, DCS, GSM, GPRS, GLONASS, and more. Using an optional external antenna such as our OPTO-LPA12G provides even more accuracy and function. The OPTO-SA6200 has a built-in tracking generator that measures frequency response for passive/active devices. The OPTO-SA6200 can interface to a PC via USB to transfer data. A built-in 5000mAh Battery provides 8 hours of operation on a full charge for a full day of field use.
​
OPTO-SA6200 Features
-
Handheld RF Spectrum Analyzer, sweeps range of 35MHz to 6200 MHz in 0.25 seconds
-
Signal Generator
-
Built-in Tracking Generator measures frequency response of passive/active devices
-
LCD Large 3.2" Color touch screen display with stylus included
-
High Accuracy of 2dB within 70-75dB dynamic range
-
Measure SWR when using an external directional coupler
-
PC Interface with USB to transfer data
-
Can detect Wi-Fi, 2G, 3G, 4G, LTE, CDMA, DCS, GSM, GPRS, GLONASS
-
Built-in Battery with 8 Hour operation
-
Includes 1 USB Data Cable, 2x 30cm RG405 SMA Cables, 1 SMA F Connector, 1 Stylus
-
Size: 5.91 x 2.95 x 0.91 inches; 13.4 ounces

OPTO-SA6200 Included Accessories
OPTO-SA6200
$499



OPTO-LPA12G
Logic Periodic Directional Antenna
100 MHz - 12 GHz Range
High Gain 7 - 12 dBi
SMA cable & BNC adapter included
​
$249


*Optional OPTO-LP12G Antenna Sold Separately
OPTO-SA6200 Technical Specifications
​​
Display frequency range: 35-6200 MHz
Measuring frequency range: 35-6200 MHz
Dynamic range of 35-3000 MHz frequency band: 75 dB
Dynamic range of 3000-4500 MHz frequency band: 70 dB
Maximum span: 6165 MHz
Bandwidth: 200 kHz, fixed
Check the scanning speed of the frequency band above 100MHz: 700MHz/sec
Scan 100 MHz:<0.25 seconds
Background noise up to 3000 MHz: <-90dBm
Background noise 3000-4500 MHz: <-85dBm
Background noise 4500-6200 MHz: <-80dBm
WaveImpedance: 50 Ω
StandingWave ratio within the operating frequency range: <1,5
Internal attenuator: 0-30 dB
Error at attenuation up to 10 dB: 2 dB
10 to 20 dB attenuation error: 5 dB
20 to 30 dB attenuation error: 8 dB
Output power of tracking generator: -15 to -25 dBm
Accuracy in dynamic range: 2.0 dB
Maximum input power of attenuator at 0 dB: 10 dBm
Maximum input power when attenuation is greater than 20dB: +20dBm
Maximum input measurement signal:+10 dBm
Size: 5.91 x 2.95 x 0.91 inches; 13.4 ounces